SYMPTOMS POSSIBLE REASON CORRECTIVE ACTION
Leaking Flapper chain is too tight Adjust flapper chain for proper slack
Flapper chains jammed Clean obstruction
Lever of solenoid valve cannot put back down after used Clean obstruction
Not flush Loosen of flapper chain Reconnect flapper chain and secure
Solenoid valve do not work after used Connect the connector form solenoid valve to main control unit
Poor flush Flapper chain too slack Adjust flapper chain to remove excessive slack
Flush time is set too short Adjust flush time
Active indictor (red light) does not off Dust on glass Clean glass with soft cloth
Sensor blocked Remove block object or reclocate sensor
Sensor range too long Adjust detecting range
Active indictor (red light) does not on No battery power Replace battery or plug in Adapter
Flush unsuitably when not in use Sensor blocked Clean obstruction or reloacte sensor unit